** PRICE AVAILABLE ON REQUEST**
Turbine: SHIN NIPPON
Rated Output Generator terminal: 44,500 Kw
Operating Conditions:
Speed (turbine/generator): 3000 / 3000 rpm
Inlet steam pressure: 68.06 barA
Inlet steam temperature: 447 deg C
Exhaust steam pressure: 0.136 barA
Un-controlled Extraction: at Turbine nozzle
Max. 2nd Extraction pressure: 1.94 barA
Un-controlled Extraction: at Turbine nozzle
Max. Inlet flow: 194600 kg/hr
Max. 1st Extraction flow: 25880 kg/hr
Max. 2nd Extraction flow: 9870 kg/hr
Max. Exhaust steam flow: 158750 kg/hr at 0.253 barA
Three-phase Synchronous Generator :MEIDENSHA COPRPERATION
Quantity One
Type EK-AFT
Prime Mover Steam Turbine
Standard IEC 60034
Rating Continuous / 56,250kVA-2P-11kV-50Hz-2,952A-0.8pf
Site Operating Conditions a. Altitude Not exceed 1,000m above sea level b. Ambient temperature Maximum 41°C c. Installation Indoor, Non-hazardous area
Excitation System Brushless type with AC exciter and PMG
Construction a. Type of Rotor Cylindrical b. Winding connection Star c. Number of poles 2 d. Rated speed 3,000min e. Over speed 120%
Noise Level (at Vent discharge) 85dB at no load Rev.1
Insulation Class of Winding
Temperature Rise of Winding
Lubricating Oil System Lubricating oil is fed from the common lubricating oil unit provided by the prime mover supplier.
Lubrication Forced lubrication
Three-phase Synchronous Generator DAIHEN ELECTRIC CO, LTD
Quantity One
Type 3-phase, Oil immersed, Outdoor
Standard IEC 60076
Installation Outdoor
Type of cooling ONAN/ONAF
Capacity 45,000/56,250kVA Rev 1
Frequency 50Hz
Voltage Primary (Low tension) side: 11kV Secondary (High tension) side: 132kV
Connection Primary side: Delta Secondary side: Star and neutral solidly grounded
Insulation class A
Insulation level 11kV 132kV a. Lightening impulse withstand voltage 75kV 650/-kV b. Power frequency withstand voltage 28kV 275/38kV
Site Operating Conditions a. Altitude Not exceed 1,000m above sea level b. Ambient temperature Maximum 41°C c. Installation Outdoor, Non-hazardous area
Type of termination 11kV Cable box 132kV Outdoor
Tap changing device On load tap changer
Shin Nippon 44.5MW turbine Generator unit
condition report has been undertaken machine, has been serviced and maintained while in storage to keep its integrity.
machine has never been used and remains in orginal packaging (only unsealed for maintenance)
information regarding condition and mainternce can be provided.